Simultaneous UPLC Assay for Oxitropium Bromide and Formoterol Fumarate Dihydrate in Pressurized Metered Dose Inhaler Products for Chronic Obstructive Pulmonary Disease


Seckin S., Aslan S. S.

Journal of AOAC International, cilt.107, sa.2, ss.242-247, 2024 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 107 Sayı: 2
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1093/jaoacint/qsad134
  • Dergi Adı: Journal of AOAC International
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Applied Science & Technology Source, BIOSIS, CAB Abstracts, Chemical Abstracts Core, Chimica, Compendex, Food Science & Technology Abstracts, MEDLINE, Veterinary Science Database, DIALNET
  • Sayfa Sayıları: ss.242-247
  • İstanbul Üniversitesi Adresli: Evet

Özet

Backround: Oxitropium bromide (OB) and formoterol fumarate dihydrate (FFD) are inhaler molecules that are widely used in the treatment of chronic lung diseases. Objective: The goal of this work was to create a reversed phase–ultra performance liquid chromatography (RP-UPLC) technique for assay and identification of OB and FFD, as well as identification and estimate of its associated compounds in pressurized metered dose inhaler product (pMDI). Method: Separation of oxitropium and formoterol peaks were enhanced on a C18 (50 × 2.1 mm × 1.7 lm) UPLC column with ethylene-bridged-hybrid technology, The mobile phase consists of buffer (0.07 M KH2PO4) and acetonitrile (80:20, v/v). The detector wavelength of 210 nm, flow rate of pump 0.6 mL/min, and oven temperature for column were set at 25̊C. The injection volume was 10 lL. The method run time was 2 min. The mobile phase was used as the solvent. Results: Retention times (RTs) were 0.5 min for OB and 1.0 min for FFD. The assay analysis was linear range for all analytes within the range for concentrations 0.03—14.8 mg/mL of OB, 0.01–0.88 mg/mL of FFD. LOD values and LOQ values 0.009 and 0.026 mg/mL for OB and 0.003 and 0.009 mg/mL for FFD, respectively. Recoveries were obtained at 96.3% for OB and 97.2% for FFD. Precisions values were (as RSD, %) ≤1.5%. Conclusions: With the UPLC method developed and validated according to the current ICH guidelines, it is possible to simultaneously detect OB and FFD of assay analysis in pMDI products accurately, precisely and selectively, independent of the matrix effect. Highlights: The present method is the first method in the literature based on the UPLC method for this purpose. The UPLC method is a time-saving method, it provides a faster and cheaper technique than the high performance liquid chromatography (HPLC) method.